DIFLEX Technical datax
Class |
Condizioni di fornitura | Service | Working Pressure | Working Temperature |
85 | -colour: Grey or white -printed: "Diflex Diflon Milano" -sheet size: 1500x1500 mm /1500x3000 mm -sheet thickness: 0.5-1-1.5-2-3 mm (tollerance: +/- 10%) |
Highly corrosive fluids (hydrofluoric acid, chlorinated petrochemicals). pH: 0 ÷ 14 | ?60 bar. PxT:12000 (bar x C°) |
-200° C +260° C |
Caratteristiche | Metodo di prova | Unità di misura | Valori |
Density Permeability (2) -sp 2 mm -sp 3 mm Strain Tensile strength Tensile strength Creep relaxtion -sp 2 mm -sp 3 mm Compressibility Ritorno elastico Heat cnductivity factor Spealing coeff. m -sp 2 mm -sp 3 mm Spec. pressure y -sp 2 mm -sp 3 mm Compressive Strength (3) Compressive Strength (4) |
ASTM D1457 DIN 3535 at 40 bar DIN 3535 at 40 bar ASTM D 621 ASTM F 152 ASTM F 152 ASTM F 38B ASTM F 38B ASTM F 36 ASTM F 36 DIN 52612 ASTM F 586/89 ASTM F 586/89 ASTM F 586/89 ASTM F 586/89 60 N/mm2 at 23°C 30 N/mm2 at 150°C |
g/cm3 cm3/min cm3/min % MPa % % % % % W/M.K. - - N/mm2 N/mm2 % % |
2,24 0,003 0,004 6,5 >12 450 52 68 16,7 40÷50 0,40 2,75 2,00 25,5 11,02 21 32 |
Unless otherwise indicated, values refer to 2 and 3 mm thicknesses.
Note:
(1) For lower temperatures, please contact our technical office.
(2) The "DIN 3535" test sets the maximum leakage rate at 1 cm³/min. Permeability values are well below this limit.
(3) This test is carried out in order to measure the % surface increase after one minute under a pressure of 60N/mm² at room temperature.
(4) This test is carried out in order to measure the % surface increase under a load of 30 N/mm² after having heated the gasket for 45 min. as to gradually increase its temperature to 150°C, and maintaining it for 30 min.